Dell EMC VxFlex OS Server-Based SAN (E22-214) Certification Sample Questions

DC Dumps, E22-214 Dumps, E22-214 PDF, DC VCE, Dell EMC E22-214 VCE, Dell EMC DEC PDFThe purpose of this Sample Question Set is to provide you with information about the Dell EMC VxFlex OS 2.x Server-Based SAN exam. These sample questions will make you very familiar with both the type and the difficulty level of the questions on the E22-214 certification test. To get familiar with real exam environment, we suggest you try our Sample Dell EMC VxFlex OS Server-Based SAN Certification Practice Exam. This sample practice exam gives you the feeling of reality and is a clue to the questions asked in the actual Dell EMC Certified VxFlex OS 2.x Server-Based SAN (DEC) certification exam.

These sample questions are simple and basic questions that represent likeness to the real Dell EMC E22-214 exam questions. To assess your readiness and performance with real time scenario based questions, we suggest you prepare with our Premium Dell EMC VxFlex OS Server-Based SAN Certification Practice Exam. When you solve real time scenario based questions practically, you come across many difficulties that give you an opportunity to improve.

Dell EMC E22-214 Sample Questions:

01. Where are ScaleIO 2.0 Installation Manager logs located in a Microsoft Windows system?
a) C:\Program Files\emc\scaleio\im\logs
b) C:\Program Files\emc\scaleio\lia\logs
c) C:\Program Files\emc\scaleio\inst_mgr\logs
d) C:\Program Files\emc\scaleio\gateway\logs
 
02. Which ScaleIO caching option provides a write-back functionality?
a) CacheCade on SSD drive
b) RFCache on Flash Card
c) XtremeCache on SSD drive
d) XtremCache on Flash Card
 
03. How does ScaleIO practically eliminate capacity planning and migrations?
a) I/O parallelism ensures that the ScaleIO workload is evenly distributed among servers, allowing for linear scaling
b) ScaleIO is hardware agnostic, it can be deployed virtually anywhere
c) ScaleIO scales to over 1000 servers, allowing customers to adopt a pay-as-you-grow model aligning with application needs
d) ScaleIO capacity may be added or removed without interruption and will automatically be rebalanced or rebuilt
 
04. At the top-most level, what are major selectors for types of views available in the ScaleIO 2.0 GUI?
a) Reports, Backend, and Alerts
b) Dashboard, Backend, and Alerts
c) Dashboard, System, and Alerts
d) Dashboard, System, and Reports
 
05. In a VMware environment, what is a benefit of using a supported RAID controller in each ScaleIO Data Server (SDS)?
a) Faster SDC access to metadata information
b) Better performance with multiple SVMs per ESXi server
c) Faster deployment with the use of raw device mapping for SDS devices
d) Higher availability with more than two copies of each volume chunk
 
06. What is the major benefit of ScaleIO over other software defined storage offerings?
a) Compression and deduplication functionality drive costs down
b) Converges host-based storage to reduce cost, storage and compute can be added modularly
c) Simpler to deploy and has better performance features, without hidden costs
d) Offers better performance, control, compliance and security than other solutions
 
07. You are performing a remote support session to a ScaleIO system. After opening the ScaleIO GUI, you notice that the hardware tab is missing. How would you explain it?
a) Advanced Management Services (AMS) has not been used to deploy the system
b) AMS is down or disconnected from the network
c) The ScaleIO installation has VMware nodes only
d) AMS is running on customer provided hardware
 
08. Which visual monitoring interface grants a way to check the system health in a ScaleIO environment?
a) REST Gateway
b) ScaleIO GUI
c) ScaleIO CLI
d) LIA
 
09. A customer needs to copy data and modify that copy without modifying its source. Which ScaleIO feature meets this need?
a) Fault set
b) Clone
c) Tie Breaker
d) Snapshot
 
10. What must be considered before the system administrator creates fault sets in a ScaleIO 2.0 cluster?
a) Number of volumes defined in the storage pool
b) Number of SDC's that need to map volumes
c) Total capacity required to protect data in the fault set
d) Number of protection domains needed by the fault sets

Answers:

Question: 01
Answer: d
Question: 02
Answer: a
Question: 03
Answer: d
Question: 04
Answer: b
Question: 05
Answer: c
Question: 06
Answer: c
Question: 07
Answer: a
Question: 08
Answer: b
Question: 09
Answer: d
Question: 10
Answer: c

Note: For any error in Dell EMC Certified VxFlex OS 2.x Server-Based SAN (DEC) (E22-214) certification exam sample questions, please update us by writing an email on feedback@edusum.com.

Rating: 4.9 / 5 (34 votes)